Below ground drainage systems installation guide
CI/SfB( )In6OCTOBER 1999OUIG4BELOW ground drainage SYSTEMSINSTALLATION GUIDECONTENTS PAGEBelow ground drainage SystemsResources and Planning4Transport4Handling4Storage5Inst allation Notes6Excavation6Bedding6-7Backfill Sequence8Pipe Protection8-9Installation of TwinWall Pipes10-11OsmaDrain SystemContents12Installation Information13-34Osma UltraRib SystemContents35Installation Information36-45Wavin TwinWall SystemContents46Installation Information47-49Below ground drainage SystemsTesting50Safety50Maintenance50Gen eral Information51Acceptance52Abbreviations52 Below ground drainage SYSTEMSContents3BELOW ground drainage systems installation GUIDETable 1. Size of Block BundlesNominal Number ofDimensionsWeightPipe3m/6m lengthsin mmper bundle kgSizeper bundleheightwidth3m6mOsmaDrain1105072511 45246492160258651035230460Osma UltraRib15024655970158304225127309701733 273009966970227Wavin TwinWall1503311801000-2972251411801000-2 35300811801000-264RESOURCES AND PLANNINGThe main contractor, or sub-contractor,needs no special equipment or are responsible for checking lay-out drawings to ensure they
a captive ring seal. b) Osma UltraRib Sealing rings are supplied either loose with pipes and fittings or pre-fixed in the case of Inspection Chamber and Manhole Bases and are included in the price. c) Wavin TwinWall Sealing Rings are supplied loose with pipes and fittings if required, all pipe and fitting prices are exclusive of ring seals, and ...
Download Below ground drainage systems installation guide
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document: