PDF4PRO ⚡AMP

Modern search engine that looking for books and documents around the web

Example: bachelor of science

Exit Detector - cerber.pro

Back to document page

ExitDetectorINSTALLATION INSTRUCTIONSTechnical SpecificationsDetector typePassive InfraredFilter technologyDigital Signal Processing ( ) Detector lensCurtain type Fresnel lensDetection rangeOne hand: 3m (10 ft.) / Whole body: 6m (20 ft.)Power consumption 12-28 volts DC, 50 mAPiezo buzzer90 dB at 28V, 5-28 volts DC,20 mA. (XL & XL2 only)Main relay contacts SPDT,1A max. at 30 volts DC relay timerAdjustable, 1/2 to 60 secondsMain relay recycle timeFixed, 3/4 second offLock control 2A max at 30 volts DCTime fixed at 2 seconds (LT2 & XL2 only)Tamper , 100mA max at 30 volts DC L x W x D7-1/8"L x 1-3/4"W x 1-7/8"DIndicator lightRed/Green LEDCertificationUL 294, CE, FCCInstallationRefer to the illustration below for the recommendedmounting positions. When selecting an appropriatemounting position, keep in mind the potential for airdrafts or objects to be passed through gaps aroundthe door and into the detection cable entry opening into the is on theright back side, near the cover retaining screw.

Exit Detector INSTALLATION INSTRUCTIONS Technical Specifications Detector type Passive Infrared Filter technology Digital Signal Processing (D.S.P.)

  Exit, Detectors, Exit detector