mounting instructions - KLINGER
Summary of the eight versions of KLINGER SWGs, the designprinciple,materialsand Wound GasketsKLINGERmaxiflex mounting instructionsThe principleThe KLINGERmaxiflex function isbased on the metal winding/ filler re-lationship and the flange surface roughness should beapprox. m. KLINGERmaxiflexgaskets can be used in flanges withlarger surface roughnesses, but in thiscase the bolt loads should be increa-sed so as to ensure proper function ofthe gasket. When the KLINGERmaxiflex gas-ket is compressed during mounting ,the homogeneous filler flows intothe irregularities of the flange. Themetal windings enclose the filler and,at the same time, ensure the strengthand elasticity of the the gasket is equipped with anPTFE filler it must have an inner ringsince the PTFE permits no furthercompression, as is the case with otherfillers.
Summary of the eight versions of KLINGER SWGs, the design principle, materials and mounting instructions. KLINGER Spiral Wound Gaskets KLINGERmaxiflex
Download mounting instructions - KLINGER