PREFERRED RELIABILITY PRACTICES FAILURE MODES, …
PRACTICE NO. PD-AP-1307PREFERREDPAGE 1 OF 2RELIABILITYPRACTICES FAILURE MODES, EFFECTS ANDCRITICALITY analysis ( fmeca )JETPROPULSIONLABORATORYPractice:A nalyze all systems to identify potential FAILURE modes by using a systematic study starting at the piecepart or circuit functional block level and working up through assemblies and subsystems. Requireformal project acceptance of any residual system risk identified by this :The fmeca process identifies mission critical FAILURE modes and thereby precipitates formalacknowledgment of the risk to the project and provides an impetus for design that Certified Usage:Viking, Voyager, Magellan, GalileoCenter to Contact for More Information:Jet Propulsion Laboratory (JPL)Implementation Meth
PRACTICE NO. PD-AP-1307 PREFERRED PAGE 1 OF 2 RELIABILITY PRACTICES FAILURE MODES, EFFECTS AND CRITICALITY ANALYSIS (FMECA) JET PROPULSION LABORATORY Practice: Analyze all systems to identify potential failure modes by using a systematic study starting at the piece