Technical Specification - cogeneration.com.ua
GE Jenbacher GmbH & Co OHGA-6200 Jenbach, AustriaJMS 416 gas +43 5244 600-0Fax +43 5244 63255Jenbacher gas enginesTechnical SpecificationJMS 416 gas Module data:Additional information:Electrical outputkW pressure level (engine, average value 1m)dB(A)95Recoverable thermal output (120 C) pressure level exhaust gas (1m, 30 off engindB(A)115Energy gas mass flow rate, Consumption based on a LHV ofExhaust gas volume, wetNm ,5 kWh/Nm Nm exhaust back pressure after enginembar60Electrical efficiency%42,9%Exhaust gas temperature at full load C [8]370Thermal efficiency%43,3%Combustion air mass flow efficiency%86,2%Combustion air volumeNm to be dissipated (LT-Circuit)kW90Max. inlet cooling water temp. (intercooler) C40Emission values:Max. pressure drop in front of intake-air filtermbar10NOx < 310 ppm (0% O2) Return temperature C70 Forward temperature C90 Hot water flow ratem /h49,0Engine data:Alternator:Engine typeJ 416 GS-A09ManufacturerSTAMFORDConfigurationV 70 TypePE 734 E2No.)
Basic engine equipment: Module equipment: *Exhaust gas turbocharger, Intercooler *Base frame for gas engine, *Motorized carburator for LEANOX control …
Download Technical Specification - cogeneration.com.ua
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Related search queries
G670 Intermittent Pilot Ignition Controls Technical, CONTROL, Control Valve Technical Specification, Specification, Gas Fired Boiler SPECIFICATION, Technical specification, Valve, HART Field Device Specification Fisher, HANDBOOK FOR CONTROL VALVE SIZING, TECHNICAL, Control valve, Fire security standard technical specification, Automatic sprinkler fire extinguishing system