Ultrafiltration Efficiency During Automated …
Advances in peritoneal dialysis , Vol. 24, 2008Ultrafiltration EfficiencyDuring AutomatedPeritoneal dialysis UsingGlucose-Based SolutionsThe Ultrafiltration (UF) Efficiency of peritoneal di-alysis (PD) solutions , defined as the net UF dividedby the amount of carbohydrate absorbed per dwell,has been shown to be higher During long dwells icodextrin solution (Extraneal: BaxterHealthcare Corporation, Deerfield, IL, ) thanduring those with glucose-based solution ( dianeal : Baxter Healthcare Corporation),prompting a better understanding of UF used the three-pore kinetic model of PD trans-port to investigate UF Efficiency for single long dwellsand various combinations of multiple short glucose-based dwells During Automated PD (APD)
Advances in Peritoneal Dialysis, Vol ... during those with glucose-based solution (2.5% and 4.25% Dianeal: ... the dextrose concentration in the dialysis solution.
Download Ultrafiltration Efficiency During Automated …
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Related search queries
Peritoneal, Peritoneal dialysis, Dianeal, Solution, PRESCRIBING INFORMATION, DIANEAL peritoneal dialysis, EXTRANEAL, Peritoneal Dialysis Solution, Peritoneal Dialysis Prescription and Modalities, Dialysis solution, Physician Assistants, Pharmacy Staff, Dianeal Peritoneal Dialysis Solution, Dianeal PD4 Dianeal PD101, Dianeal PD4 . Dianeal PD101, Nutrineal PD4, Price List & Product Catalog | 2011, PEriTONEal dialYSiS Dianeal, Dianeal Peritoneal, Dianeal® Peritoneal Dialysis Solutions