1 DETERMINATION OF clearance DISTANCES FOR venting OF HYDROGEN STORAGE Tchouvelev, , Benard, , Agranat, and Cheng, & Associates Inc., 6591 Spinnaker Circle, Mississauga, ON, L5W 1R2 Canada 2 Hydrogen Research Institute, University of Quebec, Trois Revieres, Quebec, Canada 3 Hydrogenics Corp., 5985 McLaughlin Road, Mississauga, ON, L5R 1B8 Canada ABSTRACT This paper discusses the results of computational fluid dynamics (CFD) modeling of hydrogen releases and dispersion outdoors during venting of hydrogen storage in real environment and geometry of a hydrogen refueling or energy station for a given flow rate and dimensions of vent stack.
4 condition is s 1.41 4124 293.15 1305.61 m 2 2 0 c = g H R H T = × × = . The hydrogen venting should be considered under either choked or subsonic release according to the venting stack size.