Transcription of ALLEN BRADLEY / GUARDMASTER - …
{{id}} {{{paragraph}}}
RSafety SwitchesTongue Switches3-28MT-GD2 Visit our website: S117-CA001A-EN-PGeneral1-2-Opto-electron ics3-InterlockSwitchesOperatorInterfaceL ogicPowerDescriptionFeaturesMT-GD2 Latch Release StyleSpecifications Strong and versatile, can be used in most applications Eight possible actuator entry points, easy to install Variety of contact configurations Snap acting MT-GD2 gives a min. break contact force of 40 N Optional latch release styles Industry standard fixing centers to DIN/EN50041 safety RatingsStandardsEN954-1, ISO13849-1, IEC/EN60204-1,NFPA79, EN1088, ISO14119, IEC/EN60947-5-1, ANSI , ClassificationCat. 1 device per EN 954-1 dual channelinterlocks suitable for Cat. 3 or 4systemsFunctional safety Data Note: For up-to-date information,visit : > 2 x 106operations at min. loadPFHD: > 3 x10-7 MTTFd: > 385 yearsDual channel interlock may be suitablefor performance levels Ple or Pld(according to ISO 13849-1:2006) and foruse in SIL2 or SIL3 systems (accordingto IEC 62061) depending on applicationcharacteristicsCertifications CE Marked for all applicable directives,cULus, T V, and CCCO utputsSafety Contacts Standard: 3 or 2 directopening actionSnap acting: 2 direct openingforced disconnectionAuxiliary ContactsStandard: 1 or 2 Acting: 2 CurrentIlth10 ARated Insulation Voltage(Ui) 500 VSwitching Current @ Voltage, Mi
R Safety Switches Tongue Switches 3-30 MT-GD2 Visit our website: www.ab.com/catalog Publication S117-CA001A-EN-P General 1 …