ANNEX SPECIFICATION FOR STRUCTURES TO BE …

ANNEX . SPECIFICATION FOR STRUCTURES TO BE BUILT IN DISASTER AREAS. CHAPTER I - GENERAL PRINCIPLES. SCOPE. - Requirements of this SPECIFICATION shall be applicable to newly constructed buildings as well as to existing buildings. - Provisions to be applied for the prevailing buildings of which the intended use and / or carrier system shall be changed, the performance shall be evaluated before or after the earthquake and buildings to be strengthened were given in Section - 7. - Requirements of this SPECIFICATION shall be applicable to reinforced concrete (cast-in-situ and pre - stressed or non - pre - stressed prefabricated) buildings, structural steel buildings and building-like STRUCTURES , and timber, masonry and adobe buildings.

3 CHAPTER 2 - ANALYSIS REQUIREMENTS FOR EARTHQUAKE RESISTANT BUILDINGS 2.0. NOTATION A (T) = Spectral Acceleration Coefficient A o = Effective Ground Acceleration Coefficient