PDF4PRO ⚡AMP

Modern search engine that looking for books and documents around the web

Example: biology

Aptima - Quest Diagnostics

Aptima . Specimen collection and processing guide Aptima Multitest Swab Specimen processing guide Accept After sample collection, Align the score line with the top Swab will drop to bottom of the immediately hold swab in the edge of the tube and carefully vial. Screw cap on tightly and transport tube so the black score break swab shaft. Visually inspect send to lab for processing. line is at top of the tube. to confirm the swab is broken at score line. Break here Reject Supply # 180028. Product: A03. DO NOT break above score line. DO NOT cut or fold swab in half. DO NOT use wooden or any other swabs. Aptima Urine Specimen collection procedure Supply # 180029. Product: A01. Overfilled Underfilled Accept Reject Reject Transfer urine into Overfilling or underfilling will require a new sample collection tube. collection tube to obtain a valid result.

QuestDiagnostics.com Quest, Quest Diagnostics, any associated logos, and all associated Quest Diagnostics registered or unregistered trademarks are the property of Quest Diagnostics.

Loading..

Tags:

  Quest

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Spam in document Broken preview Other abuse

Transcription of Aptima - Quest Diagnostics

Related search queries