PDF4PRO ⚡AMP

Modern search engine that looking for books and documents around the web

Example: stock market

Calibrating Boom Sprayers - USDA

Calibrating boom Sprayers 9 Clean the tanks to remove any sand or other abrasive material that could clog screens and cause wear on the pump and nozzles. 9 Fill the tank with clean water. 9 Clean the suction and line strainers . 9 Remove nozzle tips, strainers , and boom end caps. 9 Clean and inspect the nozzle tips and strainers . 9 Make sure all of the nozzles are the same size and type. 9 Run the sprayer and flush the boom and all hoses with clean water. (Never operate the pump without liquid in the tank) 9 Reinstall nozzles and strainers and replace any worn or damaged parts. 9 Replace boom end caps. 9 Run the sprayer again and check connections for leaks. 9 Adjust the pressure regulator to the desired operating pressure and run the sprayer again. 9 Collect the spray from each nozzle for a given amount of time to see if nozzle output is uniform.

Clean the suction and line strainers. Remove nozzle tips, strainers, and boom end caps. Clean and inspect the nozzle tips and strainers. Make sure all of the nozzles are the same size and type. Run the sprayer and flush the boom and all hoses with clean water. (Never operate the pump without liquid in the tank)

Loading..

Tags:

  Line, Boom, Sprayers, Usda, Calibrating, Strainers, Line strainers, Calibrating boom sprayers

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Spam in document Broken preview Other abuse

Transcription of Calibrating Boom Sprayers - USDA

Related search queries