Transcription of Capacitor reforming guide - ABB
{{id}} {{{paragraph}}}
ACS800. Capacitor reforming guide Capacitor reforming guide ACS800. Code: 3 BFE64059629 REV C EN. EFFECTIVE: FIDRI\EIF200. PDM code: 2006 ABB Oy. All rights reserved. 3. Table of contents Table of Capacitor reforming guide ..4. How to check the converter reforming time ..4. Converters stocked (non-operational) less than 2 Converters stocked (non-operational) for 2 years and over ..5. Method 2 A: ..5. Method 2 B: ..6. Table of contents 4. Capacitor reforming guide Introduction This guide applies to single drive frequency converters and multidrive inverter units, referred as converters later in this document. Converter DC link capacitors need to be reformed (re-aged) if the converter has been non-operational for more than one year. Without reforming capacitors may get damaged when the converter starts to operate. It is recommended to reform the capacitors once a year.
Capacitor reforming guide . 6 R C A U2 V2 W1 W2 V1 U1 Disconnect FREQUENCY CONVERTER UDC- UDC+ Ux Ux SUPPLY UNIT INVERTER UNIT Figure 2. Reforming circuit for method 2 A Table 1. Component values for reforming Recommended components A R C 380 V < U× < 415 V SKD 82/16 220 Ohm / 700 W 22 nF / 2000 V