PDF4PRO ⚡AMP

Modern search engine that looking for books and documents around the web

Example: confidence

Chapter 3 Pre-Installation, Foundations and Piers

Page 1 of 14 Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design , materials, access, and installation of manufactured dwellings, accessory structures, accessory buildings, earthquake-resistant bracing, and wind and flood resistant anchoring. design Loads Except as otherwise stated, the manufactured dwelling siting, foundation, and installation requirements contained in this code are based on the following: o Minimum soil bearing capacity is 1,000 PSF o Minimum pier capacity of 4,000 lbs. o Roof live load of 30 lbs PSF o Horizontal wind load of 15 PSF Note: Additional design loads are specified in Section Basic Requirements Regardless of the type of foundation system provided, the foundation must assure the manufactured dwelling has adequate support, a level floor, flush roof, flush floor, and flush wall connections at the marriage lines of multi-section manufactured dwellings.

activity three seismic design categories have been established in Oregon as shown on Figure 3-2.5(a). o Design Category C – low risk o Design Category D 1 - medium risk o Design Category D 2 – high risk Design category C and D 1 Manufactured dwellings are limited to(1): o 3 feet in height for 75% of the under-floor area, and o 5 feet – 7 ...

Loading..

Tags:

  Design, Seismic, Oregon, Categories, Seismic design categories

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Spam in document Broken preview Other abuse

Transcription of Chapter 3 Pre-Installation, Foundations and Piers

Related search queries