Page 1 of 10 Chapter 6 Electrical Connections 6-1 General All Electrical equipment and installations must be designed, constructed, and installed in accordance with this code and where not specific, to the applicable provisions of the oregon Electrical Specialty Code. Alternate methods permitted in the oregon Electrical Specialty Code, but not mentioned in this code may be permitted if acceptable to the building official. See Section All Electrical equipment, materials, devices, appliances, and fittings must be listed and labeled for it s intended use, and installed according to this code and where not specific, to the oregon Electrical Specialty Code.
Electrical equipment or materials may not obstruct the access to the under-floor area. Conduit must be installed and secured at the intervals required in Table 6-2.3(c). Feeders must be connected to the electrical service disconnect within view of the manufactured dwelling and within 30 ft. of the manufactured dwelling exterior wall.