CHAPTER-6 governing system - IIT Roorkee

147 CHAPTER-6 HYDRO- turbine governing system (Reviewed by Dr. R. Thapar) Introduction governing system or governor is the main controller of the hydraulic turbine . The governor varies the water flow through the turbine to control its speed or power output. Generating units speed and system frequency may be adjusted by the governor. governing system as per IEEE std. -75 includes following. a) Speed sensing elements b) Governor control actuators c) Hydraulic pressure supply system d) turbine control servomotors-these are normally supplied as part of turbine TO (SPEED SIGNALGENERATOR)TURBINEFLOWCONTROLW ICKETGATES ORNEEDLEHYDRAULICAMPLIFIERSERVOMOTORPILO TSERVOMOTOROR HYDRAULICTRANSDUCERCONTROLSPEEDSENSINGSP EED(FREQUENCY)SIGNAL FROM PT(SHP ONLY)GOVERNORLEVEL,OTHERSUPERVISORYCONTR OLSET POINTS ADJUSTMNETS(DROOP;JOINT CONTROL)TECHOMETERSPEEDSW ITCHESFEED BACK Figure : governing system Block Diagram (Typical) The primary functions of the hydraulic turbine governor are as follows: i) To start, maintain and adjust unit speed for sy

electronic loads controllers are used and shunt load bank is adjusted. 6.2 Governor Capacity (oil servomotor) Governor capacity rating in meter-kilogram is the capacity of the wicket gates/nozzles and blade servo motors (Kaplan units) as required for operation of the turbine at minimum rated oil pressure. USBR

Loading..

Tags:

  Turbine, Electronic

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Spam in document Broken preview Other abuse

Transcription of CHAPTER-6 governing system - IIT Roorkee

Related search queries