Transcription of CHAPTER-6 governing system - IIT Roorkee
{{id}} {{{paragraph}}}
147 CHAPTER-6 HYDRO-TURBINE governing system (Reviewed by Dr. R. Thapar) Introduction governing system or governor is the main controller of the hydraulic turbine. The governor varies the water flow through the turbine to control its speed or power output. Generating units speed and system frequency may be adjusted by the governor. governing system as per IEEE std. -75 includes following. a) Speed sensing elements b) Governor control actuators c) Hydraulic pressure supply system d) Turbine control servomotors-these are normally supplied as part of turbine TO (SPEED SIGNALGENERATOR)TURBINEFLOWCONTROLW ICKETGATES ORNEEDLEHYDRAULICAMPLIFIERSERVOMOTORPILO TSERVOMOTOROR HYDRAULICTRANSDUCERCONTROLSPEEDSENSINGSP EED(FREQUENCY)SIGNAL FROM PT(SHP ONLY)GOVERNORLEVEL,OTHERSUPERVI
In Pelton units it requires positioning of spear and deflector. Pressure oil system with oil servomotor is most commonly used actuator. In micro hydros electronic loads controllers are used and shunt load bank is adjusted. 6.2 Governor Capacity (oil servomotor)
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
{{id}} {{{paragraph}}}