TI416P/24/ InformationDeltapilot S FMB70 Hydrostatic Level MeasurementPressure sensor with the CONTITETM measuring cell, water proof and long-term stability; Communication via HART , PROFIBUS PA or FOUNDATION FieldbusApplicationThe hydrostatic pressure sensor is used for the following measuring tasks: Hydrostatic pressure measurement for liquids (both high and low viscosity) in food, beverage, dairy and pharmaceutical applications Level, volume or mass measurements Ideal for balance tank applications High accuracy and zero point stability for use in large silo tanksYour benefits Excellent reproducibility and long-term stability Hermetically sealed CONTITETM measuring cell: Protection against condensate and washdowns Linearity (better than of the set measuring range) High reference accuracy: Minimum temperature effects, F(better than ) Thick membrane for additional protection against mechanical damage Used for process pressure monitoring up to SIL3, certified according to IEC 61508 by T V S D HistoROM /M-DAT memory module Function-monitored from the measuring cell to the electronics Continuous modularity for differential pressure, hydrostatic and pressure (Deltabar S Deltapilot S Cerabar S), replaceable display universal electronics Quick commissioning with quick setup menus Easy and safe menu-guided operation on-site, via 4 to 20 mA with HART, PROFIBUS PA or via FOUNDATION Fieldbus
Deltapilot S FMB70 Endress+Hauser 5 Overview of process connections on FMB70 Design Connection Version Standard Approval Nominal diameter Nominal pressure/Class