DEP8053 (April 2011) 401 KAR 42:030. CONTINUITY TESTING PROCEDURE FOR. Impressed Current Cathodic Protection SYSTEMS. Fixed Cell Moving Ground Continuity Test Procedure 1. Place reference electrode in contact with the soil at a location remote (25 100 feet) from all cathodically protected structures. You must ensure that the remote reference electrode placement is not in proximity to any other Cathodic Protection systems ( natural gas pipelines) or directly over any buried metallic structure in order to minimize the chances of unwanted interference.
DEP8053 (April 2011) 401 KAR 42:030
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
{{id}} {{{paragraph}}}
Isolated Current and Voltage Measurement Using, Using, Phase AC Current Measurement Using, Phase AC Current Measurement Using Current Transformer, Transformer, Current, Voltage, INSULATION POWER FACTOR TESTING of, Specifications, National Instruments, Isolated, User Guide, HBL Battery Charger uses Thyristor switching