DEP8053 (April 2011) 401 KAR 42:030. CONTINUITY TESTING PROCEDURE FOR. Impressed Current Cathodic Protection SYSTEMS. Fixed Cell Moving Ground Continuity Test Procedure 1. Place reference electrode in contact with the soil at a location remote (25 100 feet) from all cathodically protected structures. You must ensure that the remote reference electrode placement is not in proximity to any other Cathodic Protection systems ( natural gas pipelines) or directly over any buried metallic structure in order to minimize the chances of unwanted interference.