Transcription of DEUTZ EMR3 - Diagnostic trouble codes
{{id}} {{{paragraph}}}
DEUTZ emr3 - Diagnostic trouble codesDEUTZ Service Information Systems1/2025-Jan-2006 Table 1: Errors sorted by functional groupFunctional groupComponent /LocationDescription (Error location)Defined forErrorcodeSERDIAIDB linkcodeSPNFMISelf-curing1 DCRDMVI nput monitoringAccelerator pedalCable break or short circuit, signal implausible compared to signal of idle sensor (analog pedal)zz12 APP12-2-691 2, 3, 4, 11 Cable break or short circuit, bad PWM signal range or frequency (digital pedal)zz14 APPPwm2-2-2912, 8zBad PWM pulse-width repetition rate (digital pedal)zz15 APPPwmPer2-2-2918, 11zBatteryVoltage below target rangezz22 BattCD3-1-81680, 1, 11zCharge air pressure sensorCable break or short circuitzz32 BPSCD2-2-31022, 3, 4zCharge air temperature sensorCable break or short circuitzz149 IATSCD1-2-8105 2, 3, 4, 11zCoolant temperature sensorCable break or short circuitzz 55 CTSCD2-2-51102, 3, 4zCustomer-specific sensorCable break or short circuit (sensor 1)zz136 GOTSCD1-3-3- 2, 3, 4, 11zCable break or short circuit (sensor 2)zz139 HOTSCD3-1-41638 3, 4, 11, 12zEngine speed sensorEngine running with cam-shaft speed signal onlyzz75 EngMBackUp2-1-219011, 12zSpeed signal from cam.
DEUTZ EMR3 - Diagnostic trouble codes DEUTZ Service Information Systems 3/20 25-Jan-2006 Engine protection Air filter condition Pressure loss above target range with system reaction zz11 AirFltSysReac 1-3-6 107 1, 11 z Battery voltage Above target range with system reaction zz23 BattCDSysReac 3-1-8 168 2, 11 z Charge air pressure Outside target range with system …