1DH152 & DR152 Typical Installation Instructions & Warranty InformationDuplex Station150-Gal. Capacity2 Environment One Grinder Pump Feature Identification1. GRINDER PUMP BASIN Polyethylene2. ACCESSWAY COVER HDPE 3. ELECTRICAL QUICK DISCONNECT (EQD) Cable from pump core terminates POWER AND ALARM CABLE Circuits to be installed in accordance with local codes. 5. ALARM PANEL NEMA 4X enclosure. Equipped with circuit breakers. Locate according to local ALARM DEVICE Every installation is to have an alarm device to alert the homeowner of a potential malfunction. Visual devices should be placed in very conspicuous INLET EPDM grommet ( ID). For OD DWV WET WELL VENT tank vent, supplied by factory in units with GRAVITY SERVICE LINE 4 DWV, ( OD).
codes. A dedicated 30 amp breaker is required before a 240V duplex alarm panel, and a dedicated 40 amp breaker is required before a 120V duplex alarm panel. 8. ELECTRICAL CONNECTION: (Pump to Panel) (Fig. 4) The grinder pump station is provided with a cable for connection between the station and the alarm panel (supply cable).