DuraPlus - DuraVent
The minimum height of the registered trademark symbol ® shall be 3/64 of an inch. When the overall diameter of the UL Mark is less than 3/8 of an inch, the trademark symbol may be omitted if it is not legible to the naked eye. ... Combustible materials include lumber plywood, sheetrock, plaster and lath, furniture, curtains, electrical wiring ...
Tags:
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
Round and Oval Type B GasVent Type B Gas Vent Systems for ...
duravent.comon other gas-burning appliances, provided the manufacturer of the appliance states in their installation instructions that Type B-vent is acceptable. Do not use Type B Vents for Category II, III, or IV gas appliances. Type B Vent shall not be used to vent flue products from incinerators, combination gas/ oil appliances, oil-fired, or wood-burning
DuraVent Product Bulletin
duravent.comDuraVent Product Bulletin “New” DirectVent Pro Wall Thimble for 5x8 applications. Wall Thimbles allow for a complete wall pass through and firestop.
DuraTech - duravent.com
duravent.comSpeci˜cations Applications 5”-8” DuraTech is a double-wall, all-fuel chimney system for use with wood stoves, ˜replaces, furnaces, boilers, ranges, water heaters, or other
Type B Gas Vent - DuraVent
duravent.comconnected to pipe sections. Saves time and money on installation. Aluminum inner pipe Aluminum inner pipe heats up faster. Remains hot during operation and eliminates condensation in the appliance and vent system. Double-Wall Wye-45° Branch Can be used in place of tees to provide a 45° angle instead of 90°. Branch swivels on male end for
DuraTech - DuraVent
duravent.comFirestop Radiation Shield DVL/DuraBlack Chimney Adapter Extended Roof Bracket 7 4 10 9 2 19 7 6 8 5 18 1 4 Attic O˜set Cathedral Ceiling w/Support Box 18 1 6 8 4 7 2 4 12 7 13 11 17 8 3 19 1 ... ney extends 5’ or more above the roof penetration an extended roof bracket is required. An additional roof bracket is needed every 5’. • Measure ...
DVL® - DuraVent
duravent.comMOBILE HOMES: Solid fuel appliances installed in mobile homes must be listed and bear the label of a testing agency approved by the Department of Housing and Urban Development (HUD), and must be installed exactly in accordance with the manufacturer’s installation instructions. DuraVent’s DVL stovepipe complies with the requirements
DuraTech - DuraVent
duravent.comDuraTech 5"-8" With a Refractory insulation encased between dual walls, DuraTech oflers the optimum in safety and performance. It keeps the outer wall of the chimney cool while ensuring high ffue gas temperatures for optimum draft performance. The inner wall is 25% thicker than competitive chimneys for an extra margin of safety.
Type 1 vs. Type 2 Exhaust Hoods - DuraVent
duravent.comWhat is a Commercial Cooking Appliance? The definition of commercial cooking appliance under IMC Section 202 and the kitchen exhaust hood provisions under IMC 507.2 do not provide specific demarcations to answer this question for every situa-tion and circumstance. Whether a cooking appliance is a commercial
Related documents
Techincal Note: Fire-Retardant-Treated (FRT) Plywood
inspectapedia.comwood plywood shall be determined in accordance with ASTM D 5516. The test data developed by ASTM D 5516 shall be used to develop adjustment factors, maximum loads and spans, or both, for untreated plywood design values in accordance with ASTM D 6305. Each manufacturer shall publish the allowable maximum loads and spans for service
Fire, Plywood, Treated, Retardant, Shall, Plywood shall, Fire retardant treated
HYDRAULIC HOSE FITTINGS & ADAPTERS - ALFAGOMMA
www.alfagomma.comConstruction Pulp and Plywood Mills GLOBAL COMPANY Due to our world-wide organisation of subsidiaries and distributors you will always be near a source for ALFAGOMMA products. Your ALFAGOMMA dealer has ... of any kind whatsoever shall be refund of the purchase
Shoes, Fitting, Hydraulic, Plywood, Adapter, Shall, Hydraulic hose fittings amp adapters
INSPECTION CHECKLIST Residential Re-roof
mybuildingpermit.comPlywood or Oriented Strand Board Sheathing ... inch air space shall be provided between the insulation and roof sheathing and at the location of the vent. (R806.3) Final Inspection Proper installation of roof covering. Fasteners installed as required for the type of roofing material and per
Checklist, Residential, Roof, Inspection, Plywood, Shall, Inspection checklist residential re roof
ISPM 15. Regulation of wood packaging material in ...
www.fao.orgThe original English edition shall be the authoritative edition. Disputes arising under the licence that cannot be settled amicably will be resolved by mediation and ... (e.g. plywood). The phytosanitary measures described in this standard are not intended to provide ongoing protection
Regulations, Packaging, Material, Woods, Plywood, Regulation of wood packaging material, Shall
USG DUROCK BRAND GLASS-MAT TILE BACKERBOARD
www.usg.comThe subfloor shall be APA Span-Rated Plywood or OSB with an Exposure 1 classification or better with tongue and groove or back blocked at the unsupported edges. 4. Do not use where temperature will be above 120°F (49°C). 5. Maximum dead load for ceiling system is 7.5 psf. 6. Steel framing must be 20-gauge equivalent or heavier.
Glass, Ielts, Brand, Plywood, Shall, Backerboard, Brand glass mat tile backerboard
Installation Guide - James Hardie Pros
www.jameshardiepros.com• Use minimum 5/8 exterior grade plywood or 23/32 OSB with Exposure 1 classification or better, complying with local building codes and ANSI A108.11. • Joist spacing not to exceed 24 in on center. • The floor must be engineered not to exceed the L/360 deflection criteria (L/720