Transcription of E-STOP relays, safety gate monitors
{{id}} {{{paragraph}}}
E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1. pnoz X9. Unit features ` safety gates ` Light barriers ` Positive-guided relay outputs: 7 safety contacts (N/O), instanta- safety features neous 2 auxiliary contacts (N/C), in- The relay meets the following safety stantaneous requirements: ` 2 semiconductor outputs ` The circuit is redundant with built-in ` Connection options for: self-monitoring. E-STOP pushbutton ` The safety function remains effec- safety gate limit switch tive in the case of a component fail- Reset button ure. safety relay for monitoring E-STOP Light barriers ` The correct opening and closing of pushbuttons, safety gates and light ` LED indicator for: the safety function relays is tested barriers. Switch status channel 1/2 automatically in each on-off cycle. Supply voltage ` The tranformer is short circuit- Approvals Reset circuit proof.
E-STOP relays, safety gate monitors Up to PL e of EN ISO 13849-1 PNOZ X9 Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany NSG-D-2-037-2009-04 Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de