ELECTRIC ACTUATORS - AUMA
A typical example of multi-turn valves are gate valves. They require a defined number of turns at valve input for a complete valve stroke from CLOSED to OPEN and vice versa. Butterfly valves or ball valves are typically used if part-turn movements up to 90° are required for the entire travel. Globe valves are normally operated via linear movement.
Tags:
Valves, Ball, Ball valves, Auma
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
Operation & Instructions Manual SA 3 - SA 100 SAR 3 - AUMA
www1.auma.comQuad ring Oil seal Oil seal Ball bearing Circlip Circlip Circlip Circlip Circlip Snap ring Lid Blinker switch (SPST) Spring washer Lock washer Lock washer Fillister head screw Support washer Star washer Dog drive sleeve (type C) Thrust ring Keyway drive sleeve (type B) Drive socket (type E) Stud bolt Flat washer Hexagon nut Cap Hexagon head ...
Electric part-turn actuators - Auma
www1.auma.comElectric part-turn actuators Operation instructions SG 05.1 – SG 12.1 SGR 05.1 – SGR 12.1 AUMA NORM for flange type FA
Electric, Part, Turn, Actuator, Electric part turn actuators
Electric multi-turn actuators - Auma
www1.auma.comElectric multi-turn actuators Operation instructions SA 07.1 – SA 48.1 SAR 07.1 – SAR 30.1 AUMA NORM for flanges type FA
Multi, Electric, Turn, Actuator, Electric multi turn actuators
Actuator controls AC 01.2/ACExC 01 - AUMA
www1.auma.com6.5. Operation mode EMERGENCY stop 35 6.6. Operation mode Disabled 35 6.7. Operation mode Service 36 ... Operate to position via push buttons of the local controls 76 8.14.8. Operate to position from Remote 77 8.14.9. Dead band 77 8.14.10. Correction of inertia 78 8.14.11. Backlash compensation 78 8.14.12. Signalling behaviour of positions: set ...
Post, Emergency, Push, Button, Push buttons, Auma, Emergency stop
Related documents
General Utility Service Needle Valves - Swagelok
www.swagelok.comVALVES BALL PLUG VALVES CHECK RELIEF VALVES GU SEIES NEEDLE REGULATORS & FILTERS INSTRUMENT MANIFOLD SSTEMS MEASUREMENT DEVICES REFERENCES MEDIUM- HIGH- PRESSURE TUBE ... emissions to atmosphere for rising stem valves. The tests are conducted at a third party lab and certify that at no point in the test did the valve leak …
Services, General, Utility, Valves, Ball, Needle, Stem, Swagelok, Rising, Valves ball, General utility service needle valves, For rising stem valves
Bolted Bonnet OS&Y Wedge Gate Valves - API 600 Class: …
www.scvvalve.comRising Stem Ball RSB1006B1036RGFT-HR Rising Stem Ball, 10”, 600#, Bolted Bonnet, WCB Body, 316SS Trim, HNBR Seals, RPTFE Seats, Raised Face, Gear Operated BAL 02 01 B 13 13 R L FT - H D X Figure Number Profile No. Figure Number Code Description 1 Valve Type Identifies the valve body design (gate, globe, ball, plug, etc.)
Valves, Gate, Ball, Stem, Bolted, Bonnet, Wedge, Rising, Bolted bonnet os amp y wedge gate valves, Rising stem ball
LEAD FREE Series LF009 - Watts
media.wattswater.comNRS – non-rising stem resilient seated gate valves OSY – UL/FM outside stem and yoke resilient seated gate valves S-FDA – FDA epoxy coated strainer QT-FDA – FDA epoxy coated quarter-turn ball valves LF – without shutoff valves Note: The installation of a drain line is recommended. When
VANESSA SERIES 30,000 - Triple Offset Valves
www.vanessavalves.emerson.comrising stem valve. Furthermore, the quarter turn rotation eliminates any negative effects on packing caused by rising stems, such as extrusion and abrasion, improving valve performance and reducing fugitive emissions. ... ball and globe valves and, with our long face-to-face valves (designed in accordance to
Valves, Ball, Stem, Rising, Rising stem
GUIDANCE ON VALVE TYPE SELECTION -b.ricardo
blog.projectmaterials.comHand operated gate valves usually have the following stem arrangements: Inside screw, non-rising stem. Outside screw, rising stem. a. An outside screw, rising stem valve should be the normal first choice as it is easier to maintain, allowing access for lubrication of the thread. In marine environments the rising stem and threads should be ...
CPI™ / A-LOK Tube Fittings and Instrumentation Valves
www.parker.comU16 Series Medium Pressure Valves..... 126-127 Manual Toggle Valves VQ Series..... 128-129 Needle Valves NP6 Series..... 130 Needle Valves SN6 Series..... 131 Rising Stem Plug Valves PV Series ..... 132-133 Overview..... 134-135 Medium Pressure Gauge Valve
CAST IRON VALVES CATALOG - Walworth
walworth.comIron Gate Valve Rising Stem (OS & Y) 2" to 36" Bronze 125# FF W726 F Iron Globe Valve Rising Stem (OS& Y) 2" to 12" Bronze 125# FF W906 F Iron Swing Check Valve 2" to 24" Bronze 125# FF W928 F Iron Gate Valve Non Rising Stem 2” to 36” Bronze 125# FF W719 F Iron Swing Check Valve with lever & counter weight 2” to 24” Bronze 125# FF W928F LCW
SECTION 15183 - REFRIGERANT PIPING
www.abpenc.com2.02 VALVES A. Lines 1” O.D. or smaller: Diaphragm Packless Valves: 500-psig working pressure and 275 deg F working temperature; globe design with straight-through or angle pattern; forged-brass or bronze body and bonnet, phosphor bronze and stainless-steel diaphragms, rising stem and hand-wheel, stainless-steel spring, nylon seat disc,
Section, Refrigerant, Valves, Stem, Rising, 11853, Rising stem, Section 15183 refrigerant
Valves, Fittings and Tubing
www.autoclave.comValves incorporate a rising stem/block design while the non-rotating feature of the stem prevents galling. In addition, the valves are designed with metal to metal seating for bubble tight shut-off, long stem/seat life even in abrasive flow conditions, and excellent overall corrosion resistance. Valve Pattern options are shown in the next section.
LEAD FREE Series LF909 - Watts Water
media.wattswater.comStrainer Dimensions SIZE (DN) DIMENSIONS WEIGHT M N1† N in. mm in. mm in. mm in. mm lbs. kgs. 21⁄2 ⁄65 10 25461 2 1652812.7 3 1080 1⁄8 257102547 1783415.4 4 ⁄100 121 8 3081230581⁄4 2106027 6 ⁄150 ⁄181 2 47020508131 2 34313360 8 21200 5785 ⁄8 549223⁄4 151 2 394247112 10 26250 66028711181⁄2 470370168 † – Dimension required for screen removal