Energy Dispersive X-ray Spectroscopy (EDS)
Fluorescence •X-ray traveling through sample has energy E x > E c of element B •X-ray absorbed by atom B •Atom B de-excites •Characteristic X-ray emitted from atom B Csmpl = Kcstd ZAFsmpl/ZAFstd E NiKα = 7.47 kV FeKα E c = 7.11 kV
Tags:
Energy, Dispersive, Spectroscopy, Fluorescence, Energy dispersive x ray spectroscopy
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
How to prepare IR samples? - NUANCE Center
www.nuance.northwestern.eduHow to prepare IR samples? 1. Materials for sample preparation The following table lists the typical IR materials for various applications.
Tuschel Career Biography Molecular Spectroscopy …
www.nuance.northwestern.eduTuschel Career Biography . David Tuschel is currently the Manager of Raman Applications at HORIBA Scientific. In this capacity he manages support of customers in applied Raman spectroscopy.
Scientific, Career, Spectroscopy, Biography, Horiba, Raman, Raman spectroscopy, Horiba scientific, Tuschel career biography, Tuschel
LabRAM HR - NUANCE Center
www.nuance.northwestern.eduRaman Spectroscopy Systems LabRAM HR Spectroscopy Suite Powered by: Cutting-Edge Applications with the LabRAM HR Pharmaceuticals ... Deeply involved in Raman spectroscopy for decades, HORIBA Scientific has been providing an extensive array of Raman instruments for diverse applications.
Scientific, Spectroscopy, Horiba, Raman, Raman spectroscopy, Horiba scientific, Labram hr, Labram, Labram hr spectroscopy
What is FT IR? - Northwestern University
www.nuance.northwestern.eduInfrared (IR) spectroscopy is a chemical analytical technique, which measures the infrared intensity versus wavelength (wavenumber) of light. Based upon the wavenumber, infrared light can be categorized as far infrared (4 ~ 400cm‐1), mid infrared (400 ~ 4,000cm‐1) and near
Particle Analysis Using ImageJ - Northwestern University
www.nuance.northwestern.eduParticle Analysis Using ImageJ Note: In order to do particle analysis efficiently, all images should be taken at the same magnification with similar contrast. 1) Open the ImageJ software available on the SemUser’s computer. This is the middle computer in the sample prep area of EPIC OR you can download ImageJ for free on your
Related documents
Virology Techniques - Texas A&M AgriLife
agrilife.orgor fluorescence, designed to identify the virus of inter-est are used. This label then enables the visualization of the virus cluster (because a single virus is too small to see with a light microscope) with the light micro-scope, in the case of peroxidase, or an ultraviolet (UV) light microscope in the case of fluorescence. Electron Microscopy
Technique, Fluorescence, Microscopy, Virology, Virology techniques
Introduction to Confocal Laser Scanning Microscopy (LEICA)
www.umassmed.eduFluorescence Microscopy. Confocal laser scanning microscope - set up: The system is composed of a a regular ßorescence microscope and the confocal part, including scan head, laser optics, computer. Higher z-resolution and reduced out-of-focus-blur make confocal pictures crisper
Statement of Purpose - Ohio Wesleyan University
www.owu.eduThis project required me to use several advanced microscopy techniques, such as confocal, fluorescence and DIC to visualize whole worms, dividing embryos, spindle formation in cells etc. For the past two summers, I have contributed to a research project in Dr. Chris
Purpose, Testament, Fluorescence, Microscopy, Statement of purpose
Two Ways to Count Cells with ImageJ - UNIGE
www.unige.chbelow details a simple count from a single color fluorescence image. For more complicated counts (multi-color images, counts from histology or brightfield image, counting cells within a region, etc.) the Microscopy Core Facility staff can help you develop a custom counting routine or macro. 1) Open the image to be counted.
With, Count, Cells, Ways, Fluorescence, Microscopy, Imagej, Two ways to count cells with imagej
Fluorescence Excitation and Emission Fundamentals
www.chem.uci.edufluorescence microscopy was responsible for a revolution in cell biology, coupling the power of live cell imaging to highly specific multiple labeling of individual organelles and macromolecular complexes with synthetic and genetically encoded fluorescent probes.
Cell Cycle Analysis - Carbone Cancer Center
cancer.wisc.eduSep 18, 2017 · There is at most a two-fold difference in fluorescence intensity between a cell in G0/G1 and a cell in G2/M. Therefore, it is best to view the DNA staining on a linear scale. Collect the Area, Height, and Width parameters for the DNA channel in addition to Forward Scatter and Side Scatter. Run the samples at a low flow rate for the best results.