1 Fertilizer Processing using Split-Online Summary On May 12-13, 2003 split Engineering preformed preliminary experimentation using the existing pellet Processing library of the Split-Online system to measure pelletized Fertilizer . The fertilizers used in the experiment came from four samples sent to us by potential clients interested in the merits of on-line real time process control of the manufacture of Fertilizer . Three of the samples were opaquely coated and produced encouraging results. The fourth sample appeared to be uncoated and translucent, and was difficult to measure because of its poorly distinguishable pellet boundaries.
2 Sample 1 DAP SGN=270 Sample 2 DAP SGN=300 Sample 3 MAP SGN~295(?) Sample 4 Ammonium Sulfate SGN=228 Test Setup For the experiment we selected a NTSC Pulnix camera with a Computar lens. The samples were put into a tray, and the tray was put onto our TT33 sample spinner.