Page 121 Wednesday, May 14, 2014 9:14 AM. CHAPTER 7. fire AND SMOKE PROTECTION FEATURES . SECTION 701 MEMBRANE-PENETRATION FIRESTOP. GENERAL MEMBRANE-PENETRATION FIRESTOP SYSTEM. Scope. The provisions of this chapter shall govern the MINERAL FIBER. materials, systems and assemblies used for structural fire resistance and fire -resistance-rated construction separation of MINERAL WOOL. adjacent spaces to safeguard against the spread of fire and PENETRATION FIRESTOP. SMOKE within a building and the spread of fire to or from SELF-CLOSING. buildings. SHAFT. Multiple use fire assemblies. fire assemblies that serve multiple purposes in a building shall comply with all of SHAFT ENCLOSURE. the requirements that are applicable for each of the individual SMOKE BARRIER. fire assemblies. SMOKE COMPARTMENT. SMOKE DAMPER. SECTION 702 SPLICE. DEFINITIONS. T RATING. Definitions. The following terms are defined in Chap- ter 2: THROUGH PENETRATION.
FIRE AND SMOKE PROTECTION FEATURES 2014 OREGON STRUCTURAL SPECIALTY CODE 123 704.2 Column protection. Where columns are required to have protection to be fire-resistance rated, the entire column