IH75190 Surface Wipe Sampling for Metals

The only official copy is on-line at the SHSD website. Before using a printed copy, verify that it is current by checking the document issue date on the website. BROOKHAVEN NATIONAL LABORATORY Safety & Health Services Division - Industrial Hygiene Group Standard Operating Procedure Number IH75190 Revision Rev23 Subject: Surface wipe Sampling for Metals Date 06/23/17 Page 1 OF 16 IH75190 Surface wipe Sampling for Metals Purpose & Scope This document describes a field procedure for taking wipe samples for Metals on surfaces . It is based on methodology described in NIOSH 9100 Lead in Surface wipe Samples of the NIOSH Manual of Analytical Methods. The goal of the procedure is to provide a uniform methodology to collect representative samples. Using this method will ensure repeatability between various Sampling personnel and between Surface configurations.

Jun 23, 2017 · competency in performing this procedure in accordance with Section 7 are ed to use this qualifi procedure. 2.2. Chain of Custody procedures: The qualified sampler is responsible for samples until they have been properly transferred to the IH Group laboratory using the 200 IH Laboratory Equipment & IH51 Sample Processing . procedure. 2.3