PDF4PRO ⚡AMP

Modern search engine that looking for books and documents around the web

Example: dental hygienist

info@lenntech.com www.lenntech.com Tel. +31-15 …

Page 1 of 8 01/23/01 Flow Configuration There are several flow configurations for RO that allow the user to get the most out of the system. This paper will cover a few of the techniques used in RO design to optimize system performance. These techniques include the use of concentrate staging and concentrate recirculation to increase recovery, permeate staging to attain ultrapure standards of separation, and permate throttling and interstage boosting to manipulate the flow distribution between stages.

• High pressure pumping unit • Membrane element assembly unit • Instrumentation and control system • Permeate treatment and storage unit • Cleaning unit The membrane assembly unit (RO block) consists of a stand supporting the pressure vessels, interconnecting piping, and feed, permeate and concentrate manifolds.

Loading..

Tags:

  Com www, Pumping, Lenntech

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Spam in document Broken preview Other abuse

Transcription of info@lenntech.com www.lenntech.com Tel. +31-15 …

Related search queries