Page 1 of 2 INJECTOR SPECIFICATION EDITION: 15 NOZZLE HOLDER APPLICATIONS : SEE PAGE 2 ASSEMBLY NO. 35516 DATED: 28-06-10 SUPERSEDES: CUSTOMER: LOMBARDINI CUSTOMER PART NO. SEE PAGE 2 TEST STAND: ISO 8984 NOTE: Reference Conventional INJECTOR 1. CALIBRATION FLUID: SAE J967 / ISO 4113 Service Manual 99118 for additional (Ref. 201) AT ROOM TEMPERATURE (70 -80 F) service information. 2. CALIBRATING HIGH PRESSURE PIPES: X 12" ( X 305 mm) ITEM NO. PART NO. QTY. DESCRIPTION 1 2 3 4 5 6 7 35517 SEE TABLE 781720 29333 32972 PAGE 2 780118 1 * 1 1 1 1 1 BODY ASSEMBLY, nozzle holder SHIM, pressure Adjusting SPRING, pressure Adjusting SEAT, spring PLATE ASSEMBLY, adapter NOZZLE ASSEMBLY, hole type (not included in nozzle holder assembly) NUT, nozzle retaining (torque to 34 40 Nm or 25 - 30 ) FOR ENGINEERING USE ONLY DATE ECN NO.

page 2 of 2 10/21/09 28/06/10 31884 32753 14 15 application and service information for holder assembly 35516 injector nozzle stanadyne part no.