Transcription of Introduction Cylinder Information - MATHESON
{{id}} {{{paragraph}}}
IntroductionCylinder Flow OrificesThe restrictive Flow orifice (RFO) is for use in conjunction withhigh purity compressed gas applications in both thesemiconductor and allied chemical industries. MATHESON Tri-Gaspioneered the development of RFO Flow Orifices are used to limit the potential danger ofan uncontrolled flow from a compressed gas Cylinder . Unchecked,the instantaneous flow from a 44 liter compressed gas cylinderfilled to 2,000 psig can be as much as 20,000 liters per minute. Byinserting an RFO into the outlet of the CGA connection the flowrate could be reduced by a factor of 100 to approximately 200 litersper restrictive Flow orifice is designed to thread into the outletofmost CGA connections that have external male threads.
Introduction Cylinder Information www.mathesontrigas.com xxi Restrictive Flow Orifices The Restrictive Flow Orifice (RFO) is for use in conjunction with
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
{{id}} {{{paragraph}}}
CGA CONNECTIONS CONNECTIONS GASKETS, Introduction Cylinder Information, Connections, INDUSTRIAL GAS, INDUSTRIAL GAS CYLINDER VALVE OUTLET CONNECTIONS, Cylinder Valve Connections, Cylinder valve inlet connections, Cylinder Connections, CGA DISS Series, Connections CGA, Instruction Manual Manuel d’ Instruction Manual, Cylinder