Transcription of IP69k tightness test - Concens
{{id}} {{{paragraph}}}
IP69k tightness test Concens A/S resundvej 7 6715 Esbjerg Att: Henning Frank Subject: IP69k dust and water test. Sample: Actuator No: Con35 - 0809 and Con50 - 0809 Applied method: The IP6X dust test has been carried out in accordance with the international standard IEC 60529 Edition 2001-02. A connection M5 for the vacuum hose has been made in the bottom part of the actuator types. A vacuum of 20mbar has been supplied to the actuators during the made M5 threaded connection for a period of 2 hours. The IPX9k water test has been carried out in accordance with the DIN Standard VDE 40050 part 9.
2008-2657-IP69k Results from the IP69k test. Before and after the IP69k test the following tests has been carried out: Actuator type Con 35: