Liquid level Measurement - Viatran

Viatran Hotline: 1 800 688 0030 3829 Forest Parkway Int l: 1 716 629 3800 Suite 500 Fax: 1 716 693 9162 Wheatfield, NY 14120 Email: Web: Technical Article Liquid level Measurement A pressure transmitter can be used to determine the Liquid level in a tank, well, river or other body of Liquid . The pressure at the bottom of a Liquid filled container is directly related to the height of the Liquid . The transmitter measures this hydrostatic head pressure and gives the resulting Liquid level . To get an accurate reading, the Measurement device needs to be located at the lowest point you want to measure; typically mounted or laying on the bottom of the container.

would exert a maximum hydrostatic head pressure of 20 feet of water column. (Assuming this is water at 4° C.) Since one foot of water column is equivalent to 0.43356 PSI, the maximum hydrostatic head pressure exerted on the base of the tank …