LP SolidStart I-JOISTS LP SolidStart I-JoistsLPI 20 plus , 32 plus and 42 plus Technical Guide Floor & Roof ApplicationsPlease verify availability with the LP SolidStart Engineered Wood Products distributor in your area prior to specifying these States Design2 Table of ContentsFloor Span Tables .. 3 Uniform Floor Load (PLF) Tables: 9-1/2," 11-7/8," 14" & 16" .. 4 -5 Uniform Roof Load (PLF) Tables: 9-1/2," 11-7/8," 14" & 16" .. 6-7 Roof Span Tables: Low Slope (6:12 or less) .. 8 Roof Span Tables: High Slope (over 6:12 thru 12:12) .. 9 Load-Bearing Cantilever Tables: 9-1/2," 11-7/8," 14" & 16" .. 10-11 Brick-Ledge Cantilevers .. 12-13 Web Hole Specifi cations: Circular Holes .. 14 IntroductionLP SolidStart I-Joists provide solid, true and uniform fl oors and ceilings for residential and commercial construction. Machine made for precise, straight lines that stay straight, they are stronger pound for pound than traditional solid sawn lumber joists, and less likely to split, shrink, twist, warp or crown.
LP® SolidStart® I-JOISTS LP SolidStart I-Joists LPI® 20Plus, 32Plus and 42Plus Technical Guide Floor & Roof Applications Please verify availability with the LP SolidStart Engineered Wood Products distributor in your area prior to specifying these products.