Current Limit VCLIM CLIM Clamp Voltage In Current Limit 0.5 V ILIM(ADJ) Current Limit Adjustability l 0.5 4 A Accuracy of Adjustable Current Limit Threshold VOUTx = VINx – 0.5V, Current Limit = 4A VOUTx = VINx – 0.5V, Current Limit = 2A l l ±8 ±15 % % ILIM(INT) Internal Current Limit RCLIMx = 0Ω, VOUTx = 0V l 4 6 9 A