Transcription of Metal cladding: U-value calculation - Steel Construction
{{id}} {{{paragraph}}}
ItIUfl! WQI 1 Metal cladding Metal cladding : U-value calculation Assessing thermal performance of built-up Metal roof and wall cladding systems using rail and bracket spacers Technical Information Sheet This Information Sheet sets out a simple method for determining U-values for built-up Metal roof and wall cladding that uses rail and bracket spacers. The method can be used to demonstrate compliance with the 2002 editions of Approved Documents L1 and L2. It enables U-values for the relevant constructions to be calculated easily using simple algorithms. Software is available, incorporating these simple algorithms, that can be used to carry out the U-value calculations.
Metal cladding: U-value calculation Built-up metal cladding with rail and bracket fixings This leaflet deals with twin skin metal roof and wall cladding that is built-up on site and which consists of: • A metal inner liner panel, usually between 0.4 and 0.6 mm thick and with a shallow profile. • A rail and bracket spacer system that creates a