Transcription of METHOD 314.0 CHROMATOGRAPHY Revision 1.0 …
{{id}} {{{paragraph}}}
1 METHOD DETERMINATION OF PERCHLORATE IN DRINKING water USING IONCHROMATOGRAPHYR evision 1999 Daniel P. Hautman and David J. Munch, US EPA, Office of Ground water and Drinking WaterAndrew D. Eaton and Ali W. Haghani, Montgomery Watson LaboratoriesNATIONAL EXPOSURE RESEARCH LABORATORYOFFICE OF RESEARCH AND ENVIRONMENTAL PROTECTION AGENCYCINCINNATI, OHIO 452682 METHOD DETERMINATION OF PERCHLORATE IN DRINKING water USING IONCHROMATOGRAPHY AND APPLICATION METHOD covers the determination of perchlorate in reagent water , surface water ,ground water , and finished drinking water using ion CHROMATOGRAPHY . single laboratory reagent water METHOD Detection Limit (MDL, defined in ) for the above analyte is listed in Table 1.
2 METHOD 314.0 DETERMINATION OF PERCHLORATE IN DRINKING WATER USING ION CHROMATOGRAPHY 1. SCOPE AND APPLICATION 1.1 This method covers the determination of perchlorate in reagent water, surface water,