- 1 - MICHIGAN UNIFORM ENERGY code RESIDENTIAL ENERGY EFFICIENCY (PRESCRIPTIVE) MAJOR POINTS Attic & crawl access doors. Gasketed & with same R-value as assembly requirement. Floors. Insulation shall be installed to maintain permanent contact with underside of subfloor decking. Basement walls. Insulated from top of wall to floor, or can do floor above for unconditioned space. Slab on grade. From top of slab downward and/or horizontal 4 below grade. Can be mitered 45 at top.

- 1 - MICHIGAN UNIFORM ENERGY CODE RESIDENTIAL ENERGY EFFICIENCY (PRESCRIPTIVE) MAJOR POINTS 402.2.3 Attic & crawl access doors. Gasketed & with same R-value as assembly requirement. 402.2.6 Floors.