Mighty Mule 350 Diagnostic Feedback A) Audible Buzzer/Alarm Feedback : 1. 1 beep with 2 seconds off: Limit switch error: The circuit board cannot read the limit switch inside the operator arm. The problem could be the connection of the power cable at the Master Inputs on the circuit board, a damaged power cable from the circuit board to the operator arm, or a malfunctioning limit switch in the operator arm. 2. 2 beeps with 2 seconds off: Memory error: the circuit board has a problem that will require testing or replacement. 3. 3 beeps with 2 seconds off: Current sensing error: If the battery is fully charged and the connections are good, the circuit board has a problem that will require testing or replacement.
Mighty Mule 350 Diagnostic Feedback A) Audible Buzzer/Alarm Feedback 1. 1 beep with 2 seconds off: ♦ Limit switch error: The circuit board cannot read the limit switch inside the operator arm. The problem could be the connection of the power cable at the Master Inputs on the circuit board, a