PDF4PRO ⚡AMP

Modern search engine that looking for books and documents around the web

Example: dental hygienist

Minimize Sulfur Pit Vent Contribution to Stack Emissions

Minimize Sulfur Pit Vent Contribution to Stack Emissions Grant Qui, Al Keller Excel Paralubes - ConocoPhillips Refining Technical Services - ConocoPhillips 2800 Old Spanish Trail 3008 MO Westlake, LA 70609 Houston, TX 77079 337-491-5464 281-293-3168 Abstract SO2 Stack Emissions approaching the EPA rolling 12 hour average of 250 ppmv limited the capacity of two parallel 90 LTPD SRU/TGU trains at the ConocoPhillips Lake Charles Manufacturing complex. Using data from a performance test by Brimstone STS on the SRU/TGU and Sulfur storage pit, a plan was developed to reduce TRS and Sulfur pit vapor Emissions allowing increased acid gas throughput. Individual plan steps and subsequent positive results are discussed.

the pit vent from sulfur storage pit are the two sources that contribute to stack SO 2 emissions.

Loading..

Tags:

  Minimize sulfur pit vent contribution to stack emissions

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Spam in document Broken preview Other abuse

Transcription of Minimize Sulfur Pit Vent Contribution to Stack Emissions