Overview Implicit Messages Explicit Messages Overview This topic describes how to transfer data between an In- sight sensor and a ControlLogix or CompactLogix PLC on an Ethernet/IP network. The examples in this topic were written assuming that you are using the following components: In- sight sensor running firmware version or higher ControlLogix or CompactLogix Controller running firmware version 15 or higher Rockwell's RSLogix 5000 programming software, version 15 or higher In- sight Add-On Profile included with the In- sight Software or newer. Implicit vs Explicit Messages Implicit Messages transmit time-critical application specific I/O data, and can be point-to-point or multicast. Explicit messages require a response from the receiving device. As a result, explicit messages are better suited for operations that occur less frequently. An instruction to change an In- sight Explorer job is an example of an explicit message. Implicit Messages This section explains how to connect a ControlLogix PLC to an In- sight sensor (running firmware version or higher), and how to send and receive EtherNet/IP implicit messages.