MLAMini-SplitLow Ambient SINGLE Zone Heat Pump SYSTEMS - R-410A - 60 Hz Bulletin No. 210861 September 2019 Supersedes August 2018 SEER up to to 2 TonsCooling Capacity - 9,000 to 24,000 BtuhHeating Capacity - 10,900 to 24,000 BtuhM22A/M33A Cassette Non-Ducted Indoor UnitMWMA Wall-Mounted Non-Ducted Indoor UnitMCFA/MCFB Ceiling/Floor-Mount Non-Ducted Indoor UnitMMDB Medium Static Ducted Indoor UnitMLA SINGLE ZONE MINI-SPLIT HEAT PUMP SYSTEMSW ireless Remote Controller (furnished with Wall-Mount, Cassette and Ceiling/Floor Non-Ducted Models)Wired Remote Controller (furnished with Medium Static Ducted Models)MLA Heat Pump Outdoor UnitRESIDENTIAL / COMMERCIAL PRODUCT SPECIFICATIONSMINI-SPLIT SYSTEMSLow Ambient SINGLE Zone MINI-SPLIT SYSTEMS / Page 2M L A 009 S 4 S - 1 PUnit Type L = Low Ambient Heat PumpSeries Type M = Mini-SplitOUTDOOR SINGLE ZONE HEAT PUMP UNITSC ooling Efficiency S = Standard EfficiencyMajor Design Sequence A = 1st Generation B = 2nd GenerationNominal Cooling Capacity 009 = tons 012 = 1 tons 018 = tons 024 = 2 tonsRefrigerant Type 4 = R-410 ARefrigerant Circuits S = SINGLE CircuitMinor Design Sequence 1 = 1st RevisionVoltage P = 208/230V-1 phase-60hzMODEL NUMBER IDENTIFICATIONWALL-MOUNTED INDOOR UNITSM WM A 012
Low Ambient Single Zone Mini-Split Systems / Page 2 MODEL NUMBER IDENTIFICATION M L A 009 S 4 S - 1 P Unit Type L = Low Ambient Heat Pump