Transcription of ORTUR LASER MASTER 2
{{id}} {{{paragraph}}}
1 Dongguan ORTUR Intelligent Technologies Co., Ltd. 56 Maxin Road, Changping Town, Dongguan 523565, Guangdong Province, China ORTUR ORTUR grounding Guide10 February 2021 ORTUR LASER MASTER 22 Dongguan ORTUR Intelligent Technologies Co., Ltd. 56 Maxin Road, Changping Town, Dongguan 523565, Guangdong Province, ChinaOrtur LASER MASTER 2 grounding AdvisoryRelease Date: 10-02-2021 ORTUR Action Advice: RecommendedSome users have been reporting and experiencing Static Electricity build up in their machines while in use, especially on raster engraving build up of Static Electricity can become severe to the point that its discharge - via the 12v rail - can cause the motherboard to reset. Therefore causing interrupted engraving operations (Alarm 3/Connection Lost errors).
Wiring the Grounding Harness to Y Axis Carriage Assembly Step #1 Use Phillips Screw Driver to remove the right most screw from the Y Axis Acrylic Bracket. Step #2 Guide the screw through the dual wire strand Ring Terminal and slide it back into the Y Axis Acrylic Bracket. Use your Phillips Screw Driver to tight back the screw into