Parallel Seismic Test Method - GEOVision

Parallel Seismic Test Method Overview Parallel Seismic (PS) is a borehole test Method developed for the determination of unknown depth of foundation elements. This Method can also detect major anomalies within a foundation as well as provide the surrounding soil velocity profile. avel s r ion is Procedure In the Parallel Seismic (PS) test Method , the exposed top of the foundation is impacted by an impulsive hammer to generate compressional or shear waves which trdown the foundation and are refracted to the surrounding soil. The refracted wave arrival itracked at regular intervals by a hydrophone oa three-component geophone receiver in acased borehole. The depth of the foundatdetermined by plotting the first arrival times as a function of depth and observing the depthwhere a change of slope occurs. Alternatively, the foundation depth can be determined by observing the depth where the signal amplitude of the first arrival energy is appreciably reduced.

Parallel Seismic Test Method . Overview. Parallel Seismic (PS) is a borehole test method developed for the determination of unknown depth of foundation