Transcription of PCEL-4302 ELECTRICAL MACHINES-II
{{id}} {{{paragraph}}}
LECTURE NOTES ON ELECTRICAL MACHINES-II PCEL-4302 ELECTRICAL MACHINES-II 5TH SEMESTER IN ELECTRICAL ENGINEERING LECTURE NOTES ON ELECTRICAL MACHINES-II SYLLABUS LECTURE NOTES ON ELECTRICAL MACHINES-II LECTURE NOTES ON ELECTRICAL MACHINES-II Disclaimer This document does not claim any originality and cannot be used as a substitute for prescribed textbooks. The information presented here is merely a collection by the committee faculty members for their respective teaching assignments as an additional tool for the teaching-learning process.
LECTURE NOTES ON ELECTRICAL MACHINES-II Fig.3.2: The effects of armature reaction in a salient-pole synchronous generator. The rotor magnetic field induces a voltage in the stator which becomes maximum in the conductors directly under the pole faces (Fig.3.2.a). When a lagging load is connected to the