Installation/ApplicationNotchedTrowelBru shCloth RagLight SprayPackaging and Coverage1. Do not apply material at higher coverages per square foot. Applying too much PermaFlash Primer will result in less adhesion than if the primer had not been used. When applied at the proper coverage, evaporation should occur within a few Nominal 1 16" (2 mm) thick layer of adhesive. Coverage, open and dry time rates can vary dramatically depending on the particular substrate and environmental conditions. Coverage rates stated herein are approximate only. If FM Global or UL approval is required, consult specific RoofNavSM or the UL Certifications Directory for specific application LifePrimer & Scrim: 24 months from manufacture dateBase: Indefinite in sealed container; Activator: 24 months; Cartridges: 12 monthsStorage ConditionsClean, dry, indoor environment, unopened containerTemperature Range (Protect from freezing)Primer: 20 F 90 F (-7 C 32 C)Cement & Scrim: 60 F 90 F (16 C 32 C)Primer Container SizeBox of six 32 oz (946 ml) bottlesPrimer Coverage Rate1150 ft2 ( m2)Cement Container SizesBase: gal ( l) pailActivator.
1. Method E, 100°F (38°C), 100 mil (3 mm) sheet 2. Working and cure times will vary depending on ambient, surface and material temperatures. 3. 1,000 gr./1,000 rev., CS-17 wheel Peak Advantage® Guarantee Information Systems Guarantee Term Any bituminous roofing system. Up to 20 years* *Can be included in Peak Advantage Guarantee for new systems.