Plumbing Guidelines for ADA Accessibility Course No: M01-004 Credit: 1 PDH Steven Liescheidt, , CCS, CCPR Continuing Education and Development, Inc. 9 Greyridge Farm Court Stony Point, NY 10980 P: (877) 322-5800 F: (877) 322-4774 Appendix A to Part 1191 - Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and FacilitiesAmericans with Disabilities Act (ADA)Accessibility Guidelinesfor Buildings and Architectural and Transportation BarriersCompliance Board (Access Board)1331 F Street, , Suite 1000 Washington, 20004-1111(202) 272-0080(202) 272-0082 TTY(202) 272-0081 Water ) that allows a person in a wheelchair to make a parallel approach to the unit (see Fig. 27(c) and (d)). This clear floor space shall comply with Water General. Accessible water closets shall comply with through EXCEPTION: Water closets used primarily by children ages 12 and younger shall be permitted to comply with Fig.
front partition and at least one side partition shall provide a toe clearance of at least 9 in (230 mm) above the floor. If the depth of the stall is greater than 60 in (1525 mm), then the toe clearance is not required. 4.17.5* Doors. Toilet stall doors, including door hardware, shall comply with 4.13. If toilet stall