PDF4PRO ⚡AMP

Modern search engine that looking for books and documents around the web

Example: tourism industry

PNEUMATIC FLOAT VALVE - okcc.com

Normally closed FLOAT valves are "off" (no output)when FLOAT is low. Air signal is "on" when FLOAT is VALVE Normally OpenNormally open FLOAT valves are "on" when FLOAT islow. Air signal is "off" when FLOAT is VALVESPECIFICATIONSFLOAT AND BODYT emperature Limit 220 FPressure Limit 200 psigMinimum Specific Gravity SGWetted Materials Brass Body; 301 SS, 304 SS, Ceramic Stainless Steel Body; 303 SS, 301 SS, 304 SS, CeramicInstallationHorizontal VALVE For side mounting to vessel, Installation arrow must point downwardVertical VALVE For top SENSORF luid Media Clean compressed air or inertgases, filtration < 40 micronsOperating Pressure 30 to 100 psigOperating Temperature 35 to 140 FValve Connections For 3/32" ID tubing ( mm)Air SupplyPort #1 OutputPort #2 VentPort #3 VALVE Operation The magnetically actuatedvalve is 3 way.

pneumatic float valve horizontal float valve – side mounting vertica l flo at v ve – top mounting 6-7/8"" 1-3/8" includedhex 1" npt 1" dia. x 2" lg.

Loading..

Tags:

  Valves, Pneumatic, Float, Pneumatic float valve

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Spam in document Broken preview Other abuse

Transcription of PNEUMATIC FLOAT VALVE - okcc.com

Related search queries