Transcription of Proline Promag P 300 - Endress+Hauser
{{id}} {{{paragraph}}}
The flowmeter for highest medium temperatures with a compact, easilyaccessible transmitterApplication The measuring principle is virtually independent of pressure,density, temperature and viscosity Dedicated for chemical and process applications withcorrosive liquids and high medium temperaturesDevice properties Nominal diameter: max. DN 600 (24") All common Ex approvals Liner made of PTFE or PFA Compact dual compartment housing with up to 3 I/Os Backlit display with touch control and WLAN access Remote display availableYour benefits Versatile applications wide variety of wetted materials Energy-saving flow measurement no pressure loss due tocross-section constriction Maintenance-free no moving parts Full access to process and diagnostic information numerous, freely combinable I/Os and fieldbuses Reduced complexity and variety freely configur
Light emitting diode is flashing. Symbols for certain types of information Symbol Meaning Permitted ... Series of steps A, B, C, ... Views A-A, B-B, C-C, ... Sections-Hazardous area. ... titanium A0017703 1) For flanges made of carbon steel with Al/Zn protective coating (DN 15 to 300 (½ to 12")) or protective