RAIN BIRD
tion. Caution! Do not install automatic drain valves on the sprinkler system mainline! The automatic drain valve, model 16A-FDV, is a spring loaded device which is installed on the sprinkler pipes or heads. It is a convenient and efficient product for removing water from the lateral pipe network running from the sprinkler system control
Tags:
System, Automatic, Rain, Bird, Sprinkler, Rain bird, Sprinkler systems
Information
Domain:
Source:
Link to this page:
Please notify us if you found a problem with this document:
Documents from same domain
ESP-LXD 2-Wire Decoder System Design Guide - rainbird.com
www.rainbird.com4 ESP-LXD 2-Wire Decoder System Design Guide Advantages of a Decoder System Aesthetics A Rain Bird ESP-LXD Decoder Controller provides transparent automatic control of the irrigation system.
Weather Stations - rainbird.com
www.rainbird.comThe WS-PRO2 Weather Station, using Rain Bird® Messenger,™ can automatically notify you wherever you are, at the central control or via text messaging or e-mail when alarm conditions exist. The WS-PRO2 sensor array records vital weather information and sends it to your computer. • WS-PRO LT • WS-PRO2 Weather Station HOW TO SPECIFY
IQ Network Communication Cartridge (IQ-NCC) - …
www.rainbird.comIQ Network Communication Cartridge 1 Welcome to Rain Bird Thank you for purchasing your new state-of-the-art Rain Bird IQ Network Communication Cartridge (IQ-NCC) for the
XF Series Dripline - rainbird.com
www.rainbird.comXF Series Dripline Design, Installation and Maintenance Guide www.rainbird.com 3 Section 1 This guide covers the basics of design, installation, and
Guide, Installation, Maintenance, Rainbird, Installation and maintenance guide www
Nozzle Sets Included/Conjuntos de boquillas …
www.rainbird.comHow To Change Nozzle / Como Cambier Boquilies Nozzle Performance Charts/Tabla de rendimiento de boquillas Nozzle Sets Included/Conjuntos de boquillas REGULAR WATER PRESSURE Presión de agua uniforme SLOPES, UNEVEN AREA Planos inclinados, áreas irregulares
2-Wire Compatible Residential Control Zone Kits
www.rainbird.com• Available in low cost residential option • Cost reduction due to wire savings • Ease of troubleshooting • Fits in a 10” valve box 2-Wire Compatible Residential Control Zone Kits
ESP-RZX Controller - rainbird.com
www.rainbird.comESP-RZX Z O N E OFF AUTO T 2 W 3 TH 4 F 5 S 6 SU 7 M 1 DATE/TIME MANUAL SCHEDULE SEASONAL ADJUST BACK OFF ON NEXT AM MD YYYY 1 Introduction Welcome to Rain Bird Thank you for choosing the ESP-RZX Controller from
ESP-LXD Controller - rainbird.com
www.rainbird.comESPLXD-M50 Base Module (included) The ESP-LXD is a controller in a cabinet with locking door manufactured with UV-resistant plastics for outdoor use.
WR2 Wireless Sensor - rainbird.com
www.rainbird.comWR2 Wireless Sensor User Manual Manual del usuario Manuel de l’utilisateur 5.5" 8.5" WR2 user manual (637469-01) EN ESMX FRCA.indd 1 2/23/2018 8:09:23 AM
Rain+Birdt
www.rainbird.comIVIV ESP-Me Advanced User Manual Contents Check Box Contents a. ESP-Me Controller (outdoor model shown) b. User Manual c. Quick Reference Guide/Programming Chart (inside controller door) d. 120VSpecial Features Card(s) depending on model e. Mounting …
Related documents
Inspection, Testing, and Maintenance Cover Sheet
osfm.fire.ca.govAutomatic Sprinkler System 5 Standpipe and Hose System 6 Private Water Supply System 7 Fire Pump 8 Water Storage Tank 9 Water Spray System 10 Foam Water Sprinkler System 11 Water Mist System 12 Concerns that are Not Deficiencies (i.e. Non-Sprinklered Areas) Yes No
System, Automatic, Inspection, Sprinkler, Automatic sprinkler systems, Sprinkler systems
FIRE DEPARTMENT CITY OF NEW YORK STUDY MATERIAL …
www.nyc.govSprinkler and/or standpipe system maintenance and inspections (FC 903.5) 1. Automatic and non-automatic sprinkler systems shall be inspected, tested and maintained as required by NFPA #25 2002 edition by a competent person holding a certificate of fitness, employed by the owner, to see that all parts of the system are in good
Fire Sprinkler Systems Monitoring
www.systemsensor.comBefore the first automatic fire sprinkler system was developed in the 1870s, a fire sprinkler system consisted of a perforated pipe, a valve, a person to open the valve, and an elevated barrel or tank filled with water. A more dependable system was created in response to increased fire loads and increased values of buildings and their contents.
Technical Guidance (Application of LPC Rules for Automatic ...
www.hkfsd.gov.hk“automatic pump supplying water to a sprinkler system from a gravity tank ” Note: Booster pump of direct connection to town main is not permitted in Hong Kong. Heading of clause 3.55 should be revised and read as “sprinkler, flush ” Note: Ceiling type sprinkler is regarded as a general term. 4 Contract Planning and Documentation
Automatic Sprinkler System Calculations
www.fa.uni-lj.siAutomatic Sprinkler System Calculations 4–73. been proposed in conformance with the requirements of the standard, the system designer can begin a series of calculations to demonstrate that the delivery of a pre-scribed rate of water application will be accomplished for
IDENTIFICATION BROCHURE FOR “Central” COMMERCIAL …
sprinklerreplacement.comORDER TO IDENTIFY THEM. Sprinkler systems contain water under pressure or compressed air/gas that can cause severe damage or personal injury if sprinklers are removed while under pressure. Proper draining of a sprinkler system by a professional sprinkler installer prior to sprin-kler removal is required to protect the building from water damage.
System, Sprinkler, Sprinkler systems, Erkl, Isrpn, Sprin kler